Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.
2017
Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…
Redox Status, Dose and Antioxidant Intake in Healthcare Workers Occupationally Exposed to Ionizing Radiation
2020
The purpose of this study was to evaluate the relationship between blood redox status, dose and antioxidant dietary intake of different hospital staff groups exposed to low doses of ionizing radiation (LDIR) (Interventional Radiology and Cardiology, Radiation Oncology, and Nuclear Medicine) and non-exposed. Personal dose equivalent (from last year and cumulative), plasma antioxidant markers (total antioxidant capacity, extracellular superoxide dismutase activity, and glutathione/oxidized glutathione ratio), oxidative stress markers (nitrites and nitrates, and lipid peroxidation) and dietary intake (antioxidant capacity using ORAC values) were collected and analyzed from 28 non-exposed healt…
High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity
2017
PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…
Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis
2017
PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…
Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography
2013
Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…
Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures
2018
Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …
Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma
2013
Purpose : The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using60Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods : Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference…
Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography
2009
The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…
Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry
2016
Over the past years there has been an increase in the assessment of eye lens doses in interventional radiology procedures. This is due to the new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) that proposes to reduce equivalent dose limit for the eye lens. The aim of this study is to make estimates of equivalent dose received by eye lens of the medical staff in interventional neuroradiology procedures. Consequently, this study presents an alternative for eye lens dosimetry. For this purpose nanoDot dosimeters based on optically stimulated luminescence (OSL) technology from Landauer Inc. product were used. The measurements obtained for …
Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry
2016
The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.