Search results for "Equivalent dose"

showing 10 items of 10 documents

Evaluation of the shielding in a treatment room with an electronic brachytherapy unit.

2017

Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h-1 at 0.25 m distance from the x-ray source to 0.1 mSv h-1 at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers…

0106 biological sciencesbusiness.industryEquivalent dosemedicine.medical_treatmentBrachytherapyBrachytherapyPublic Health Environmental and Occupational HealthTreatment roomGeneral MedicineRadiation Dosage01 natural sciences030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineRadiation ProtectionElectromagnetic shieldingCalibrationmedicineHumansScattering RadiationNuclear medicinebusinessRadiometryWaste Management and Disposal010606 plant biology & botanyJournal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Redox Status, Dose and Antioxidant Intake in Healthcare Workers Occupationally Exposed to Ionizing Radiation

2020

The purpose of this study was to evaluate the relationship between blood redox status, dose and antioxidant dietary intake of different hospital staff groups exposed to low doses of ionizing radiation (LDIR) (Interventional Radiology and Cardiology, Radiation Oncology, and Nuclear Medicine) and non-exposed. Personal dose equivalent (from last year and cumulative), plasma antioxidant markers (total antioxidant capacity, extracellular superoxide dismutase activity, and glutathione/oxidized glutathione ratio), oxidative stress markers (nitrites and nitrates, and lipid peroxidation) and dietary intake (antioxidant capacity using ORAC values) were collected and analyzed from 28 non-exposed healt…

0301 basic medicineIonizing radiationAntioxidantPhysiologyThiobarbituric acidmedicine.medical_treatmentClinical BiochemistryPhysiologymedicine.disease_causeBiochemistryArticleIonizing radiationLipid peroxidation03 medical and health scienceschemistry.chemical_compound0302 clinical medicineOxygen radical absorbance capacity (ORAC)TBARSMedicineMolecular Biologypersonal dose equivalentPersonal dose equivalentbusiness.industryEquivalent doselcsh:RM1-950Antioxidant-oxidant statusCell BiologyGlutathioneoccupational exposureOccupational exposure030104 developmental biologyantioxidant-oxidant statuslcsh:Therapeutics. Pharmacologychemistryoxygen radical absorbance capacity (ORAC)030220 oncology & carcinogenesisbusinessionizing radiationOxidative stressAntioxidants
researchProduct

High-dose-rate brachytherapy boost for prostate cancer: Analysis of dose-volume histogram parameters for predicting late, rectal toxicity

2017

PURPOSE: To determine the significance of dose-volume histogram parameters for predicting late rectal toxicity (LRT) after single-fraction high-dose-rate brachytherapy (HDRBT) boost and external beam radiotherapy (EBRT) in prostate cancer. MATERIALS AND METHODS: Three hundred patients with intermediate- or high-risk prostate cancer were included between August 2010 and March 2015. Treatment comprised a single-fraction HDRBT boost of 15.0 Gy plus EBRT (46.0 Gy delivered in 23 fractions) or an HDRBT boost of 9.5 Gy plus EBRT (60.0 Gy delivered in 30 fractions) if the seminal vesicles were infiltrated using real-time transrectal ultrasound-based planning. LRT was evaluated every 3 months after…

MaleOrgans at RiskDose-volume histogramTime Factorsmedicine.medical_treatmentBrachytherapyBrachytherapyRectumLate rectal toxicity030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancerOrgan at risk0302 clinical medicinemedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesExternal beam radiotherapyRadiation InjuriesAgedAged 80 and overProstate cancerbusiness.industryRadiotherapy Planning Computer-AssistedBiologically equivalent doseRectumProstatic NeoplasmsCommon Terminology Criteria for Adverse EventsMiddle Agedmedicine.diseaseCombined Modality TherapyHigh-Dose Rate BrachytherapyHigh-dose-rate brachytherapy boostRadiation therapyDose-volume histogram parametermedicine.anatomical_structureOncology030220 oncology & carcinogenesisRegression AnalysisDose Fractionation RadiationNuclear medicinebusinessFollow-Up Studies
researchProduct

Interobserver variability in rectum contouring in high-dose-rate brachytherapy for prostate cancer: A multi-institutional prospective analysis

2017

PURPOSE: The aim of this study was to evaluate the interobserver variability (KW) of rectum contouring, and its dosimetric consequences, for high-dose-rate brachytherapy in patients with prostate cancer across multiple institutions. METHODS AND MATERIALS: Five radiation oncologists contoured rectums in 10 patients on transperineal ultrasound image sets after establishing a delineation consensus. The D-0.1cc, D-1cc, and D-2cc rectum volume parameters were determined. The mean, standard deviation, and range of each dose-volume histogram parameter were evaluated for each patient. The JOY was determined using the coefficient of variation, and the dosimetric impacts on the total dose were analyz…

MaleOrgans at Riskmedicine.medical_specialtyCoefficient of variationmedicine.medical_treatmentBrachytherapyBrachytherapyRectumRadiation DosageStandard deviationEndosonography030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineHumansMedicineRadiology Nuclear Medicine and imagingProspective StudiesObserver VariationContouringProstate cancerbusiness.industryEquivalent doseRadiotherapy Planning Computer-AssistedRectumProstatic NeoplasmsRadiotherapy DosageOrgan Sizemedicine.diseaseHigh-Dose Rate Brachytherapymedicine.anatomical_structureOncologyContouringHigh-dose-rate brachytherapy030220 oncology & carcinogenesisRadiologyInterobserver variabilitybusinessNuclear medicineBrachytherapy
researchProduct

Obesity Triples the Radiation Dose of Stone Protocol Computerized Tomography

2013

Patients with recurrent nephrolithiasis are often evaluated and followed with computerized tomography. Obesity is a risk factor for nephrolithiasis. We evaluated the radiation dose of computerized tomography in obese and nonobese adults.We scanned a validated, anthropomorphic male phantom according to our institutional renal stone evaluation protocol. The obese model consisted of the phantom wrapped in 2 Custom Fat Layers (CIRS, Norfolk, Virginia), which have been verified to have the same radiographic tissue density as fat. High sensitivity metal oxide semiconductor field effect transistor dosimeters were placed at 20 organ locations in the phantoms to measure organ specific radiation dose…

MaleUrologyRadiographyNephrolithiasisRadiation DosageEffective dose (radiation)Imaging phantomBody Mass IndexRadiation MonitoringRecurrenceReference ValuesHumansMedicineObesityDosimeterPhantoms Imagingbusiness.industryEquivalent doseRadiation doseModels Theoreticalequipment and suppliesBody BurdenTomographyTomography X-Ray ComputedbusinessNuclear medicineBody mass indexJournal of Urology
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

2013

Purpose : The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using60Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods : Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference…

business.industryEquivalent dosemedicine.medical_treatmentBrachytherapyGeneral MedicineEffective dose (radiation)Imaging phantomRadiation therapyAbsorbed doseMedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography

2009

The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…

medicine.medical_specialtyDosimeterbusiness.industryEquivalent doseRadiographyCollimatorRadiationlaw.inventionlawfashionfashion.garmentElectromagnetic shieldingmedicineLead apronRadiologyRadiation protectionbusinessNuclear medicine
researchProduct

Eye lens equivalent dose in interventional neuroradiology based on OSL dosimetry

2016

Over the past years there has been an increase in the assessment of eye lens doses in interventional radiology procedures. This is due to the new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) that proposes to reduce equivalent dose limit for the eye lens. The aim of this study is to make estimates of equivalent dose received by eye lens of the medical staff in interventional neuroradiology procedures. Consequently, this study presents an alternative for eye lens dosimetry. For this purpose nanoDot dosimeters based on optically stimulated luminescence (OSL) technology from Landauer Inc. product were used. The measurements obtained for …

medicine.medical_specialtyDosimetergenetic structuresOptically stimulated luminescencemedicine.diagnostic_testEquivalent dosebusiness.industryInterventional radiologyeye diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiological weaponmedicineDosimetryMedical physicssense organsNuclear medicinebusinessInterventional neuroradiologyNeuroradiology2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Estimation of equivalent dose to the eye lens and hands in wrist surgery using OSL dosimetry

2016

The new recommendations of the International Commission on Radiological Protection (ICRP-2012 Publication 118) proposes reducing the limit of equivalent dose to the eye lens. For this reason, it is necessary to make estimates about received equivalent dose to the eye lens of medical staff. This study provides an alternative to dosimetry of the eye lens and hands, using dosimeters nanoDots based on optically stimulated luminescence (OSL) technology in wrist surgery procedure carried out with fluoroscopy.

medicine.medical_specialtyDosimetergenetic structuresOptically stimulated luminescencemedicine.diagnostic_testEquivalent dosebusiness.industryWrist surgeryeye diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiological weaponMedicineDosimetryFluoroscopyMedical physicssense organsEye lensbusinessNuclear medicine2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)